Choosing the right cable for Transit Projects
Tue, Jan 23
|Webinar
NFPA 130 requirements for cable and fire resistive cable system for transit projects


Time & Location
Jan 23, 2024, 12:00 p.m. – 1:20 p.m. EST
Webinar
About the event
In this webinar you will learn about NFPA 130 cable requirement for non-emergency and emergency circuit and how to select the proper cable for your Canadian transit project. We will also review installation requirement for emergency circuit and how to design emergency lighting in tunnel using UL2196/ULC S139 fire resistive cable system.
Gabriel Senechal is the Technical Product Manager at CERCO Cable.
Gabriel describes himself as "Passionate and Nerd about fire protection, fire prevention, mass transit project and engineering."
He offers presentations to engineers, government, code authorities and builders on NFPA 130 cable requirement, NFPA 502 cable requirement, ULC S139 system and firestop through penetrations system and building joints systems.
NFPA 130 Principal
SFPE Quebec Board member
CFAA Director in Ontario, Atlantic and Quebec
National research council of Canada - Fire protection
Active in 7 different TC UL/ULC committee
TC 0005 Raceways And Fitting
TC 0674 Electric Motors And Generators For Hazardous Locations
TC 0864 - Fire Protection Signaling Equipment
TC 0924 - Emergency Lighting And Power Equipment
TC 1479 - Fire Tests Of Through Penetration Firestops And Building Joint Systems
TC 2196 - Fire Resistive Cables
TC 2524 - In-Building 2-Way Emergency Radio Communication Enhancement Systems
Agenda :
NFPA 130 Non-emergency circuits
Chapter 12 wiring requirements – Non-emergency
FT4/IEEE 1202 vertical flame & smoke release test
UL 1685 vertical flame & smoke release test
Product Families – Non-emergency
Different cable for different application and mission
Questions ?
NFPA 130 Emergency Circuits
NFPA 130 Chapter 12 wiring requirements – Emergency
NFPA 130 Chapter 11 design and reliability
NFPA 130 Chapter 5 & 6 emergency circuits
NFPA 130 Chapter 10 fire alarm and communications cables
Product families - Emergency
Fire resistive testing to meet UL2196/ULC 139
Installation requirement of fire resistive cable for emergency circuit
Grounding and Bonding of fire resistive cable for emergency circuit
ULC S139 Splice of fire resistive cable for emergency circuit.
Design of lighting emergency circuit to meet NFPA 130
VFD cabling option for Jet Fan
Picture of installation and past project
Different cable for different application and mission
NFPA 130 / NFPA 502 Wire and Cable Summary
Questions ?
Tickets
TRACCS Members
$0.00
Sale endedGuests (non-members)
$0.00